Manual No. 4801-5312 Rev 6-07 Page 1 of 4
To
Pump
To Power
Plug
WHT
BLK
GRN
To
Pump
To Fan
Motor
To Power
Plug
Power Jumpers
INSTRUCTIONS
1. Disconnect all electrical power to PolarCool.
(i.e. Unplug power cord).
2. Remove cooling pads.
3. Refer to Figure 3 at lower right. Open
electrical wiring box.
4. For Single speed pump, refer to Figure 1
below. For variable speed pump, refer to
Figure 2 below. Carefully disconnect pump
wires only from terminals. Pull wires through
conduit and out of electrical box. Unbundle
pump power cord from other cords so that
pump can be removed.
5. Disconnect water hose from pump. Keep
clamp for later use in Step 11.
Tools Required
Phillips Head
Screwdriver
Small Flat Head
Screwdriver
Wire Pliers Wire Cutter
WARNING!
Before Installing Pump, Disconnect All Electrical
Power To PolarCool!
KITS
6422-0610 /KIT PC 18" Pump Replace 120V
6422-0611 /KIT PC 18" Pump Replace 230V
6422-0612 /KIT PC 24" Pump Replace 120V
6422-0613 /KIT PC 24" Pump Replace 230V
6422-0614 /KIT PC 36" Pump Replace SS
6422-0615 /KIT PC 36" Pump Replace 120V
6422-0616 /KIT PC 36” Pump Replace 230V
6422-0617 /KIT PC 48" Pump Replace 230V
Kits include pump, mounting bracket and hardware
PUMP REPLACEMENT
Figure 2 - Variable Speed Pump
Fi
g
ure 1 - Sin
g
le S
p
eed Pum
p
NOTE: Inside view
of PolarCool. For clarity, not
all internal parts are shown.
Electrical Box
(location may
vary from
picture)
Pump &
Bracket
Fi
g
ure 3
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - PUMP REPLACEMENT

ROLLSEAL, INC • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010 Manual No. 4801-5312 Rev 6-07 Page 1 of 4 ToPumpTo Pow

Seite 2

ROLLSEAL, INC • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010 Manual No. 4801-5312 Rev 6-07 Page 2 of 4 6A. For th

Seite 3 - Single Speed Wiring Diagram

ROLLSEAL, INC • 1751 Co Rd 68 • Bremen, AL 35033 • Phone 256-287-7000 • Fax 256-287-7010 Manual No. 4801-5312 Rev 6-07 Page 3 of 4 13. Connect

Seite 4

PUMP REPLACEMENT